Calculate a solar system
for a rural family with
the below appliance:
- One 18w lamp used 4
hours per day
- One 60w electric fan
used 2 hours per day.
- One 75w refrigerator
runs 24 hours per day
with compressor run 12
hours and off 12 hours..
1.
Calculate PV panel
-
Calculate total
Watt-hours per day.
(18 W x 4h)
+ (60 W x 2h) + (75 W
x 12h) = 1,092 Wh/day
-
Calculate total
Watt-hours per day
needed from the PV
modules.
Watt-hours (per day)
needed from the PV
modules = 1.3 x total
Watt-hours per day.
= 1,092 x 1.3 =
1,419.6 Wh/day.
-
Calculate the PV
modules.
With panel
generation factor at the
site location = 4.58:
Total Wp of PV panel =
1,419.6 / 4.58 = 310Wp
With PV = 110Wp
we need
310 / 110 # 3 PV modules
2. Calculate
Battery

With 3 autonomy days,
the battery capacity = 178 x
3 = 534 Ah # 600AH
WE have 3 battery
12VDC/200AH in parallel
3. Calculate solar
charge controller
TPV
module parameters:
Pm =
110 Wp, Vpm = 16.7 Vdc,
Ipm = 6.6 A, Voc = 20.7
A, Isc = 7.5 A
With battery
12VDC, we choose SPT-12YY
With 310Wp ->
charge current Ic = Wp/XX =
310/12 = 25.83A
YY = 1.2 x 10.67 =
31A, we choose YY=30
Solar charge
controller: Leonics
SPT-1230
PV module is
serial connected:
Vpm = 16.7
x 3 = 50.1 VDC
Voc = 20.7 x 3 =
62.1 V
Vpm is in MPPT range of
SPT-1230, from
26 – 75 VDC and Voc < Voc max =
96VDC
3. Calculate inverter
Total
load = 18 + 60 +
75 = 153 W
For safety, the
inverter should be
considered 25-30% bigger
size.
The inverter size should
be about 200 W or
greater.